ENERGY SAVING
1W STANDBYNIGHT MODE OF OPERATION
The intelligent on-off technology allows air conditioners to
automatically switch to an energy-saving mode when they
are in standby, which results in a drop in energy
consumption from the usual 5 W to 1 W, so 80% – 90% of
The air conditioner will automatically raise the
temperature (in cooling) or lower the temperature (in
heating) by 1°C per hour during the first two hours of
operation. After that, the temperature remains the same,
energy is saved.and the air conditioner turns off automatically after 5 hours of operation.
ECO FUNCTION
Air conditioners use the innovative ECO mode of operation
in order to save energy. By pressing the button, the air
conditioner will work in an 8-hour mode that saves 60% of
energy compared to normal mode.
CLEAN AIR
SUPER THICK FILTERCARBON FILTER
Compared to an ordinary dust filter, the super-dense filter
has a greater effect of removing dust up to 50%, and pollen up
Eliminates unpleasant odors and nicotine smoke, captures
smaller dust particles, and prevents allergies.
to 80%.
BIO FILTERSELF CLEANING
It consists of an eco filter that retains very small dust
particles, bacteria and microorganisms, and biological
enzymes that eliminate up to 95% of bacteria. And up to 99%
of dust remains trapped in the filter, making it a very effective
method of sterilization.
The exchanger of the indoor unit is cleaned automatically
after the air conditioner is stopped, so that the fan of the
indoor unit rotates for a few more minutes. backwards
which removes condensed water and bacteria from the
device.
IONIZERUV STERILIZATION
Waterfalls, forests and other places where there is a sufficient
amount of anions provide a feeling of freshness. The
advantage of the ionizer in the Korel air conditioner is
Innovative UV technology in the air conditioner
provides clean air without viruses, fungi, mold, spores,
and bacteria with an air sterilization efficiency of 99.9%.
the possibility of creating such refreshing air in your
home. Anions stimulate circulation,
improve lung function and prevent lung diseases such as
asthma.
RELIABILITY
DETECTION OF THE QUANTITY OF FREONAUTOMATIC START
The indoor unit alarms if there is a gas leak from the system or ifIf the power goes out during operation, the device will shut
there is an excess of freon in the system.down. After the power is restored, the settings saved in the device’s
memory are automatically restored.
LOW TEMP. COOLINGEMERGENCY FUNCTION
The specially designed PCB is resistant to low temperatures, and theIf an error or problem occurs on the temperature sensor,
fan speed of the outdoor unit can be changed automatically
according to the temperature. condensation. The air conditioner
can be started in cooling even when the outside temperature is
the standard air conditioner will display an error code and stop
immediately, while this air conditioner will display an error and
continue operation, in case it is needed.
down to -15°C.
8C HEATINGSELF-DIAGNOSTICS
In heating, the air conditioner can be adjusted to the temperatureIn case of malfunction, the device is automatically switched off
8°C, which makes it possible to maintain this temperature in the
room and prevents freezing inside the room.
to protect the system. In the meantime, it will display an error code
for quick service
Especially suitable for houses that are not occupied during winter
days.
COMFORT
FOLLOW ME (I FEEL)WI-FI MANAGEMENT
The remote control has a built-in temperature sensor thatControl and adjust the air conditioner via an application on
reacts to the thermal loads in the room. The device itself regulatesyour smartphone.
the temperature in the room to make the user more
comfortable.
TIMERCONDENSATE DRAINAGE ON 2 SIDES
The timer can be set to start and stop the air conditioner at any time
within 24 hours.
It is easy to connect the condensate drain to the left or right to the
connection in the indoor unit.
VALVE POSITION MEMORYSWING
The dampers will automatically return to the same position they
were in the last time the air conditioner was turned off.
It distributes cold / warm air to the maximum surface by
automatically moving the horizontal flap.
WIRE REMOTE CONTROLLERTURBO MODE
It is possible to control the air conditioner via a wired controller.When operating in turbo mode the air conditioner will
reach the set temperature in the shortest possible time.
GOLD-PLATED LAMPSSMART AIRFLOW
Evaporator and condenser fins with an anti-corrosive coatingIn cooling mode, the air blows towards the ceiling.
extend the life of the air conditioner in a specific working
environment.
In heating mode, the air blows towards the floor.
MOISTURE CONTROLCOOLING WITHOUT BLOWING
The Korel smart sensor doesn’t just detectEnjoy more pleasant cooling with the Gentle Cool Wind mode. More
the temperature of the room, but also the level of humidity. Using
the application, you can set the desired humidity level between 30
and 90%.
than a thousand micro-holes allow soft air flow. Avoid strong, direct
cold blowing – and treat yourself to the ultimate refreshment.
4D AIR FLOW
4D air flow includes up-down and right-left movements and
better distributes cold air in the room. 4D air flow in air
conditioners is designed with motorized horizontal and
vertical swing. It also ensures uniform cooling of the room through a
mechanism for multidirectional air flow.